Dial Out Locations Window 119
Access Server Administrators’ Reference Guide 8 • Dial Out
Multilink (locationConfigMultilink)
This is the number of calls to multilink together. When placing more than one call, the first call will be placed,
then once it is online, the additional calls will be dialed and multilinked together.
Connection Type (locationConnectType)
This is the type of dial out to use. The following options are available:
Manual(0)—administrator will manually initiate the call by setting status to “dial”
Continuous(1)—after the administrator initiates the first call, the server will automatically reconnect after a
30 second delay if the connection goes down.
Dial-on-demand(2)—if the access server receives data destined for the IP address or net specified for this
location, the location will be dialed. The connection will be dropped after the idle timeout or session time
-
out specified.
Idle Timeout (locationIdleTimeout)
Maximum idle time before link is shut down. Especially useful for Dial-On-Demand calls.
Maximum Session Time (locationSessionTimeout)
Maximum session time before link is shut down.
Authentication Technique (locationAuthTechnique)
Technique used to authenticate at the remote location.
Ip Filters (LocationIpFilters)
Id of up to 10 IP filters which can be assigned to this interface. See section “Ip Filters (LocationIpFilters)” on
page 119.
Modem Profile (locationModemProfile)
ID of the modem profile to use to dial to this location. If no profile is specified, the default settings from the
details page will be used.