Loop (V.54 & Telco) Diagnostics
The 2073RC offers two loop diagnostics for diagnosing the 2073RC and
any communication links. These tests can be activated via signals on the
serial port interface or the front panel switch.
Operating Local Loopback (LLB)
The Local Loopback (LLB) test checks the operation of the local 2073RC
and is performed separately on each unit. Any data sent to the local
2073RC in this test mode will be echoed (returned) back to the user
device (i.e.,characters typed on the keyboard of a terminal will appear on
the terminal screen).
Figure 12. Local loopback
To perform a LL test, follow these steps:
1. The Local Loop can be initiated from the 2073RC unit either by acti-
vating the LL signal on the DTE (if you are not sure which lead is the
RDL signal, please refer to the Appendix,) or by toggling the top
front panel switch towards the label “LLB”. The Yellow TM (Test
mode) LED will turn on to indicate a successful Local loop condition.
2. Verify that the data terminal equipment is operating properly and
can be used for a test.
3. Perform a V.52 BER (bit error rate) test bit error rate (V.52) diagnos-
tics.If the BER test equipment indicates no faults, but the data termi-
nal indicates a fault, follow the manufacturer’s checkout procedures
for the data terminal. Also, check the interface cable between the
terminal and the 2073RC.